Kyoritsu 3132A Analogue Insulation / Continuity Tester

3132A

Features

•Dust and drip proof construction. (designed to IEC 60529 IP54)
•Designed to meet IEC 61010-1 and IEC 61557 safety standard.
•1mA rated test current at the minimum resistance.
•200mA measuring current on continuity testing.
•Automatic discharge of circuit capacitance.
(Any charge stored in the circuit under test will be automatically discharged after testing.)
•Live circuit warning buzzer and neon lamp.
•Small and lightweight. Shock resistant new case material.
•AC voltmeter with linear, easy-to-read scale.
•Operates on AA, R6 × 6 dry batteries.

Specifications

Insulation Resistance

 

Test voltage: 250V/500V/1000V

Measuring ranges: 100MΩ/200MΩ/400MΩ
(Mid-scale value) (1MΩ) (2MΩ) (4MΩ)

Output voltage on open circuit: Rated test voltage+20%, -0%

Nominal current: 1mA DC min.

Output short circuit current: 1 – 2mA DC

Accuracy: 0.1 – 10MΩ/0.2 – 20MΩ/0.4 – 40MΩ (Accuracy Guaranteed Ranges) ±5% of indicated value

 

Continuity

 

Measuring ranges: 3Ω/500Ω
(Mid-scale value) (1.5Ω) / (20Ω)

Output voltage on open circuit: 4.1V DC approx.

Measuring current: 210mA DC min.

Accuracy: ±1.5% of scale length

 

AC Voltage

 

AC Voltage: 0 – 600V AC

Accuracy: ±5% of scale length

 

General

 

Safety Standard: IEC 61010-1 CAT III 600V Pollution Degree 2, IEC 61010-2-031, IEC 61557-1/2/4

IP Rating: IEC 60529-IP54

EMC Standard: IEC 61326-1

Power source: R6 (AA) (1.5V) × 6

Dimensions: 106(L) × 160(W) × 72(D)mm

Weight: 560g approx.

Included Accessories: 7122B (Test leads) Pouch for test leads, 8923 (F500mA/600V fuse) × 2, R6 (AA) × 6, 9121 (Shoulder Strap), Instruction Manual

For More Information

Contact us on 08 8347 0911 or via email below