Meriam M400 M4 Single Sensor, Handheld Pressure Transmitter Calibrator / Data Logger

M400

Meriam’s M4 Series Handheld Precision Calibrator / Data Logger delivers an impressive array of features, functions and an impressive accuracy specification. The M400 includes one pressure sensor and one mA/V instrument. Choose from differential, gauge, compound or absolute pressure types and ranges from 10″ H2O to 3000 PSIG full scale.

Need two ranges for wider utility? The M402 can be configured with any two compound or absolute type sensors. Accuracy is ±0.025% of Full Scale. Accuracy is maintained over operating temperatures from -20° to +50° C (-4° to +122° F). Data Logging is standard on all M4 Series models.

With its impressive accuracy and handheld convenience the M4 Series Calibrator/Data Logger is used in medical device manufacturing, pharmaceutical manufacturing, and laboratory settings and anywhere accuracy counts.

Features

Data Logging is standard on all M4 models. Select Data Logging
from the Setup key menu and then enter the desired Interval and
Duration parameters using the keypad controls. For M400 single
pressure sensor units, pressure, VDC and mA DC values are saved
to the SD card at each interval. M402 dual pressure sensor units log
both pressure values plus VDC and mA DC values.

The supplied SD card is located under the battery compartment
cover. Data can be moved to a host PC using the supplied USB cable
and PC utility or by inserting the SD card in a compatible PC to copy
the desired files. The M4 handhelds and SD card supports up to 100
different data log files.

All DC voltage and current measurements are made using
the same two 1/8” banana jacks located in the lower end of the
handheld. This reduces the amount of time it takes to perform
the measurement and potential errors. These jacks can provide
temporary 24V DC power and measure loop current simultaneously.
Sourcing DC volts and current is also a standard feature. Use the
Sensor key to highlight the sensor desired and then use the Setup
key to select the desired function. The Adaptive Interface Wheel
is used to set precise values or configure step or ramp sourcing
programs to test receiving devices

M400: single pressure sensor (specified by customer)
M402: dual pressure sensors – any two compound or absolute sensors, mix and match as desired
Accuracy: ±0.025% of Full Scale
Temperature Performance: Accuracy includes all affects of temperature from -20º to +50º C (-4º to +122º F)
Resolution: Selectable, Accuracy or Precision: the number of places right of the decimal necessary to display the Accuracy or Precision (typically an extra digit) for the currently selected engineering unit.
Engineering Units: Configurable to display 1 to 32 industry-standard engineering units.

Voltage & Current, Measurement, Sourcing, Sinking
DC Voltage: ±50 VDC measure, 0 – 24 VDC source
DC Current: ±100 mA DC measure, 0 – 24 mA DC source, 1 – 24 mA sink at 3-50 VDC external power
Accuracy: ±(0.015% of Reading +0.002 units)

For More Information